Karta :
|
APP N° 662
Param.:
|
|
Ultra-low spray jet control
The presence as well as the density of an ultra-low spray jet should be controlled.
|
|
|
Karta :
|
APP N° 535
Param.:
|
INI:
|
|
Color mark control on syringes
The color of the mark on syringes should be controlled.
|
|
|
Karta :
|
APP N° 512
Param.:
|
INI:
|
|
Hole presence control on catheter tubes
The presence of holes on catheter tubes should be controlled.
|
|
|
Karta :
|
APP N° 511
Param.:
|
INI:
|
|
Catheter dome presence control
The presence of a dome at the end of a catheter should be controlled.
|
|
|
Karta :
|
APP N° 451
|
Position monitoring of a rubber plug before the final positioning in a syringe
The position of a rubber plug should be controlled with regard to the outer face and inner surface.
|
|
|
Karta :
|
APP N° 447
Param.:
|
INI:
|
|
Color differentiation of plastic caps for syringes
Plastic caps used for syringes should be color controlled. It has to be taken into account, that the plastic caps are semitransparent and the surface is very glossy.
|
|
|
Karta :
|
APP N° 319
|
Differentiation of coated and uncoated syringes
Coated syringes should be distinguished from uncoated syringes.
|
|
|
Karta :
|
APP N° 310
|
Detection of a gap on adhesive plaster
The presence of a gap of the tape on an adhesive plaster should be detected.
|
|
|
Karta :
|
APP N° 308
|
Presence control of plaster in a transparent plastic bag
The presence of plaster in a transparent plastic bag should be controlled. At this, a part of the plaster is fluorescent if UV light is used.
|
|
|
Karta :
|
APP N° 294
|
Thickness control of shiny aluminum cushions
The thickness of different shiny aluminum cushions should be measured. These aluminum cushions are used for heat insulation. At this, the cushions will be transported on a conveyor belt with a very small fluctuation in height, thus the distance to the belt can be used as a reference.
|
|
|
Karta :
|
APP N° 270
|
Differentiation of front- and backside of a fleece
The front side of a fleece should be differentiated from the back side. The back side (non structured side) is UV fluorescent, whereas the plastic structured film is nonfluorescent and damps the fluorescence.
|
|
|
Karta :
|
APP N° 266
|
Detection of the section point on black nonmetallic strapping
The section point on a shiny black nonmetallic strapping should be detected optically in the reflective way.
|
|
|
Karta :
|
APP N° 257
|
Detection of transparent coating on rubber seals
The coating of rubber seals should be detected. At this, different types should be controlled with the same sensor, thus the spot size of the sensor must fit to the smallest rubber size and should of course deliver proper results from the bigger seals, too.
|
|
|
Karta :
|
APP N° 252
|
Cutoff point detection of white nonmetallic strapping
The cutoff point of white nonmetallic strapping should be detected in a reflective way.
|
|
|
Karta :
|
APP N° 222
|
Sleeve presence control on an injection needle
The presence of a sleeve on an injection needle should be controlled.
|
|
|
Karta :
|
APP N° 207
|
Detection of a gap between successive hygiene articles during the transportation in a conveyor belt
Panty liners will be transported between two belts. The beginning as well as the end of a panty liner should be detected. Furthermore, a gap between two successive panty liners should be detected. The only practicable possibility is to look through the two conveyor belts.
|
|
|
Karta :
|
APP N° 203
|
Presence control of the sleeve on an injection needle
The presence of a sleeve should be controlled.
|
|
|
Karta :
|
APP N° 198
|
Color control of blood in a laboratory glass
Blood in a laboratory glass with different liquid level should be color controlled.
|
|
|
Karta :
|
APP N° 184
|
Double layer control of fleece material
It should be differentiated between one and two layers of a fleece material.
|
|
|
Karta :
|
APP N° 162
|
Presence control of a label on a nursing pad
The presence of a label on a nursing pad should be controlled.
|
|
|
Karta :
|
APP N° 147
|
Position control of a thread on a tampon
The right position of a thread on the backside of a tampon should be controlled. Right position means in this case, that the cyan colored thread should cover nearly the whole backside of the tampon. The position of the thread must be checked through a transparent plastic film.
|
|
|
Karta :
|
APP N° 143
|
Position monitoring of hook-and-loop fasteners
The orientation of Velcro® fasteners should be controlled.
|
|
|
Karta :
|
APP N° 111
|
Drop control with a laser through beam system
The number as well as the volume of drops should be controlled.
|
|
|
Karta :
|
APP N° 105
|
Spray jet amount control
The density of the spray jet should be controlled.
|
|
|
Karta :
|
APP N° 92
|
Color differentiation of syringe capsules
Syringe capsules must be color differentiated. At this, there should be detected also an unacceptable color change from batch to batch of the same capsule type.
|
|
|
Karta :
|
APP N° 25
|
Detection of color marks on disposal diapers
Different color marks (different in color) should be detected with an inline sensor. The maximum production speed is 10 m/s.
|
|
|
Karta :
|
APP N° 11
|
Inline edge detection of a white label on a white diaper
During the assembly of diapers, the presence as well as the position of the label must be controlled.
|
|
|
Karta :
|
APP N° 4
|
Detection of the presence of the fleece during the production of disposable diapers
During the production of disposable diapers the assembling of the fleece must be checked. The production speed is approximately up to 10m/s and the height of the diapers can slightly changing. Furthermore the color of the diaper as well as the color of the fleece is white but additionally to this the fleece is fluorescent in blue under the influence of UV light.
|
|
|
Karta :
|
APP N° 3
|
Detection of the correct direction of a laminated band (front side/back side detection)
The direction of a laminated band (Gore laminated band) must be controlled. The color of the band can be white, black or red.
|
|
|
Karta :
|
APP N° 2
|
Hook-and-pile fastener (Velcro®) direction control
The task is to check the direction of the hook-and-pile fastener.
|
|